Philips Catalog No.IMH-70-D-LF 1-Lamp 70 Watt E-Vision Metal Halide Mini Square Electronic Ballast W/Side Exit Leads Operates (1) 70W M98/C143-M143/ Lamp Max Distance To Lamp 5ft. Minimum Starting Temp. -20ºC/-4ºF 90°C maximum case temperature Dim: 5in (L) x 3in (W) x 1.5in (H) Superior heat transfer relative to plastic Enhancing safety and durability Meets universal code compliance Rated Voltage: Intellivolt 120V Or 277V (50/60hz) Reduction of lamp overpowering and/or thermal stress by shutting down should the lamp EOL detection removes power from lamps when they behave erratically Or fail to ignite Reach end-of-life, enhancing safety and preventing lamp cycling INSTALLATION & APPLICATION NOTES: 1. Maximum allowable case temperature is 90°C.2. Ignition pulse is 4 kV max3. All leads are 9 inches long4. Ballast output will shutdown after 20 minutes if lamp fails to ignite5. Power must be cycled off – then on, after replacing lamp 6. Connect the red lead to the center terminals of the lamp when using screw base lamps